Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/26/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | CANCELLED PER CONTRACTOR CHRIS #270-7357 | |
| 09/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED THRU JOANN AT OFFICE BY CONTRACTOR |
|
| 09/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE NEW HOLDOWNS WHERE HOLDOWNS ARE NOT EMBEDDED PROPERLY INTO SLAB 1" SPALLING MAX PER LISTING ON HOLDOWNS 2) NAIL ALL SHEARWALLS TO APPROVED PLANS 3) FOLLOW ALL APPROVED DETAILS 4) PROVIDE A PROPER LADDER TO ACCESS ROOF FOR INSPECTION 5) NEED TRUSS PROFILES/LAYOUT APPROVED BY CITY |