Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM00942

Parcel: 138091350


Addresses:

452 W MOSSMAN RD

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/18/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/10/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/05/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval
08/15/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/13/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE SAFE ACCESS TO ROOF
2) STRAP 6 X 12 BEAM
3) PER SHEAR PANEL SW-1 2 AB'S 32" ON CENTER PER PANEL
4) PROVIDE AS BUILT FOR NEW DIRECTION TJI'S WITH ATTACHMENT DETAILS
5) STRAP HEADER 4 X AT BAY WINDOW
6) PROVIDE DETAILS FOR LEDGER ATTACHMENTS
7) FAMILY ROOM TJI'S EXPOSE A35'S