Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T08CM00940

Parcel: 14042023D

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
06/13/2008 BUILDING PRE-SLAB Approved IVRS - Inspection :*
OK TO POUR MECHANICAL PAD
06/12/2008 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
OK TO POUR LOADING DOCK DRIVEWAY & SIDEWALK
05/21/2008 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
CURB AND NOSE OF DOCK
NE RAMP ON LOADING DOCK
05/16/2008 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
OK TO POUR LOADING DOCK #4 -- 12" OC
INSTALLING CURB 2 BARS
05/14/2008 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
OK TO POUR EQUIPMENT PAD EXTENSION EXTRA #4's ADDED
05/13/2008 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
#4's 18 O.C FOR NEW A/C POD EXTENSION EPOXY REBAR SPECIAL INSPECTED
NEEDS TO MATCH ENGINEERED RFI