Permit: T08CM00935

Parcel: 116180080


Addresses:

237 N MELWOOD AV

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
05/04/2009 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
04/30/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) PLAN CALLS FOR 1" H20 LINE, 1" LINE FOR ADDITION IS TIED INTO EXISTING 3/4" DIAMETER HOUSE LINE, MAIN LINE CAN'T BE SMALLER THAN NEW LINE
2) LEAK AT TIE IN JOINT OK TO COVER ALL EXCEPT TIE IN
04/28/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) NOTE: DON'T COVER SEWER UNTIL CONNECTED TO HCS, MAINTAIN 1/4" PER FT. SLOPE, INSTALL TRACER WIRE