Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2015 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/29/2015 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/13/2012 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) LATHE PRIOR TO INTERMEDIATES 2) 2 X 4 CONSTRUCTION |
|
| 07/21/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 06/01/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE 1/2" FOR DEFLECTION MID WALLS ALL A01 2 PT BEARING TRUSSES 2) PROVIDE ENGINEERED FIX OVERKNOTCH SINGLE TOP PLATE A01GE GABLE TRUSSES 3) NAIL PROTECT PLUMBING EXT. WALLS AT OSB EXTERIOR BOTTOM PLATE |
|
| 05/20/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/11/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |