Inspection History: MECHANICAL - ABOVE CEILING

Permit Number - T08CM00920

Inspection Description - MECHANICAL - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
09/16/2008 MECHANICAL - ABOVE CEILING Approved IVRS - Inspection :*
09/12/2008 MECHANICAL - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. EA CANS HANG TOO LOW, NOT FLUSH WITH FINISHED CEILING
2. PROVIDE PLASTER GROUNDS PRIOR TO SHEETROCK, REGISTERS MUST BE MECHANICALLY FASTENED, ATTACHING TO SHEETROCK ONLY IS NOT ACCEPTABLE