Permit: T08CM00914

Parcel: 117143290


Addresses:

600 S MEYER AV


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T08CM00914

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
02/18/2009 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
01/12/2009 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CANCELED BY CONTRACTOR
12/02/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
DOOR 140 TO TOPOUT
12/01/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST FREE STANDING WALL TO 8' WITH CLEANOUTS
DOOR 140 BREEZEWAY TO 8' WITH CLEANOUTS
TO PROVIDE SPECIAL INSPECTION
11/05/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT AT RM. 121
11/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
2 @ PIERS @ SE; PORTION AS PER DETAILS #115 & 313
OK TO GROUT @ 8' (CLEAN-OUTS) INCLUDED
10/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
2 COURSES ON TOP OF ADOBE

1. INSTALL STAGGERED #5 VERTICALS 16" ON CENTER
2. TIE IN BOND BEAM TO BRICK
3. RETURN BOND BEAM REBAR DOWN INTO BLOCK AT NEW CMU WALL
4. HAVE SPECIAL INSPECTOR INITIAL YOUR COPY THAT ITEMS WERE TAKEN CARE OF
10/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. TOPOUT EAST AND WEST WALLS
2. N&S WALLS GROUTING IN ALL THREAD AND REBAR MAINTAIN 24" DEPTH
10/01/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NEW ADDITION - N & S WALLS TOPPED OUT @ 14'8";
EAST WALL @ 16' - WALLS; WEST WALL @ 18'
09/25/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NEW ADDITION
N.WALL AND S.WALL 10" FROM TOP OUT
W.WALL TO 15'11"
E.WALL TO 13'3" AT LINTEL
REST OF WALL TO 11'3"
09/19/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. EXISTING BLDG. TOPOUT
SCHNEIDER AND TERRACON ON SITE
2. EPOXY DOWELS SPECIAL INSPECTED
3. SO. WALL FROM END 20' OUT GROUTED 6' LIFT
4. NEED TO INSPECT LEDGER BOLTS BEFORE SETTING LEDGER
09/12/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
DETAIL 213 ON EAST WALL OPENING

1. 12' TO 16' N,W,S WALLS
8 TO 12 E. WALL
NEW ADDITION
2. ELEVATOR AND STAIR WALL LOWER LEVEL TOPPED OUT
09/08/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NEW ADDITION S, N, W -- 8' TO 12'
ELEVATION AND LOWER RETURNING WALL 2ND LIFT

1. SPECIAL INSPECTION ON SITE
08/28/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OK TO CONTINUE
08/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH AND WEST ADDITION WALLS TO 8'