Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM00893

Parcel: 141184430

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/11/2009 FRAMING Approved IVRS - Inspection :*
11/18/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
1) PLAN CALLS FOR 4-16D'S AT EACH STUD AT LEDGER
2) HIP RAFTER 3 CHOICES 2 X 10, 4 X 6
3) BEAM DETAIL SHOWS 4 X 8 BEAMS WITH 2 X 10 ON EACH SIDE
4) MAKE SURE ALL NAIL HOLES FILLED IN EACH HANGER
5) ROOF DECK ALREADY COVERED