Permit: T08CM00892

Parcel: 14026002D


Addresses:

2375 E CALLE PILCA


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM00892

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/29/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/12/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) EXCEPT FOR GARAGE JAMBS
05/07/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 BOLTS MINIMUM REQUIRED AT GARAGE JAMBS
2) EXTEND SHEAR PANEL TO DBL PLATE
3) 2 NAILS REQUIRED TOP AND BOTTOM METAL BRACE
4) STRAP PLATE TO BEAM REAR PORCH
5) STRAP DBL PLATE TO HEADERS DINING ROOM WINDOW
6) CHECK ROOF NAILING