Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T08CM00883
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/06/2008 | FRAMING | Approved | IVRS - Inspection :* | |
06/04/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
06/03/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANCHOR BOLTS SOUTH SIDE GARAGE WITHIN 12" OF PLATE SPLICES 2) FIX BLOCKS ABOVE FRONT DOOR 3) SEAL LOW VOLTAGE PENETRATIONS AT GARAGE 4) OVER SPAN STUDS AT TUB 5) CORRECT FHA STRAPS TOP PLATE MASTER BATH AND TOILET ROOM 6) NAIL PROTECT WIRES NORTH WEST BEDROOM 7) NAIL PROTECT WIRES BEHIND STOVE 8) NAIL PROTECT GLYCOL LINES TOP PLATE IN GARAGE |