Permit: T08CM00869

Parcel: 140266710

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/22/2008 FRAMING Approved IVRS - Inspection :*
05/21/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SAME AS BEFORE
05/20/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1 HR FIREWALL BREACHED AND KITCHEN AREA
2) DBL TRIMMER REQUIRED REAR DOOR AT 2-2 X 8
3) INSULATE BEHIND SHOWER ENCLOSURES
4) 1" CLEARANCE REQUIRED B-VENT TO COMBUSTIBLE
5) FRESH INTAKE AIR SHALL BE 10' MIN FROM PLUMBING VENTS
6) NAILS MISSING AT SHEAR P-1 IN GARAGE
7) COMPLY WITH DETAIL (B) SD-1 FOR NAILING