Permit: T08CM00855

Parcel: 138213650


Addresses:

7110 S CORONA PL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/19/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/22/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
07/17/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) WORK NOT COMPLETE
2) OK TO DRY IN
3) ENGINEERED REPAIR FOR 5 EACH A04 TRUSSES AND 1 A06 TRUSS REQUIRE CITY STAMP
4) PROVIDE OPTION DETAIL FOR PARAPET AT GARAGE NORTH WALL AS BUILT
5) IDENTIFY METHOD 6 ? ON PLAN
6) SOUTH GARAGE CLIPS OK TO COVER