Permit: T08CM00849

Parcel: 141143580

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/26/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
03/24/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER VENT SLOPE OK
2) GAS PRESSURE TEST AT ZERO POUNDS
03/17/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE MINIMUM 10 PSI TEST ON ENTIRE GAS SYSTEM WITH TEST GAUGE IN 1/10 POUND INCREMENTS AT TIME OF REINSPECTION
2. NOTE: CHECK WATER HEATER VENT, VERIFY IT IS RISING
AT 1/4" PER FOOT FROM DRAFT HOOD TO THRU CEILING.