Permit: T08CM00837

Parcel: 13423424B


Addresses:

251 S WILMOT RD

Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Date Description Inspector Results Comments
09/11/2009 STEM WALL/RETAINING WALL Approved IVRS - Inspection :*
08/24/2009 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
04/22/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
WEST END RETAINING WALL (CMU) TOP OUT - OK
04/17/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
WEST END RETAINING CMU WALL FOOTING OK
SPECIAL INSPECTION COMPLETED
04/16/2009 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
03/17/2009 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
NEED SPECIAL INSPECTION
03/16/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
EAST 210 L.F. OF SOUTH SITE WALL FROM 4'8" TO 6'8" (TOPOUT) A TOP F -- OK TO GROUT
03/09/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
EAST 210 L.F. OF SOUTH SITE WALL FROM 0' TO 4'8"
ABOVE FOOTING OK
03/02/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
EAST 210 L.F OF SOUTH SITE WALL CONTINUOUS FOOTING OK
02/25/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
SOUTH PARKING LOT CMU RETAINING WALL FOOTING
FROM SW CORNER 240 L.F. EAST TO 3RD POWER POLE
12/05/2008 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
BLDG. CENTER SPREAD
FOOTING @ GRID LINES A TO K/6 TO 7 OK
10/28/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
STEM WALLS @ LINES 3/F-K, 4/D-F, 4/D-F, 5/A-D
3 @ PIERS @ NW PORTION
OK TO POUR PROGRESS AREA
10/23/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
STEEL REINFORCEMENT IN CONCRETE STEM WALLS @
GRID LINES 10/G TO K - 9/D TO G - 8/A TO D & A/5 TO 8
10/20/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
SOUTH SIDE STEM WALLS @ GRID LINES 10/K TO 5
SPECIAL INSPECTOR HAS ACCEPTED
10/15/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
NORTH SIDE @ GRID M TO X AND EAST END FROM 5 TO 8
OK TO POUR