Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CLOSET FLANGE OK |
|
| 07/28/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* TEST AND SUPPORT AT RM 109 OK SECURE WATER AND VENT AT TOP OF WALL RM. 103 AS PREVIOUS REQUESTED |
|
| 07/22/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* POST ADDRESS 1. SUPPORT HORIZONTAL ABS AT EACH CHANGE OF ELEVATION EACH END AND BRANCH CONN. 2. ISOLATION CLAMPS ARE GREAT ISOLATORS 3. BUT DO NOT PROVIDE MUCH SUPPORT FOR OVERHEAD VENTS 4. BRACE VENT AND WATER AT P-3 RM. 103 5. TEST DOWN AT P-3 RM. 109 |
|
| 07/14/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. MEANS FOR WATER HAMMERING OK 2. CALL BACK FOR CLOSET FLANGE INSPECTION |
|
| 07/01/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. PROVIDE MEANS FOR WATER HAMMERING IN RESTROOM 2. CALL BACK FOR CLOSET FLANGE INSPECTION 3. IN WALL PIPING TEST OK IN WALL (ONLY) ON ALL PIPING |