Permit: T08CM00807

Parcel: 12112390B


Addresses:

5240 E PIMA ST

Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Date Description Inspector Results Comments
08/28/2008 ENGINEERING - FINAL Approved ACCESSIBLE PARKING DELETED FROM PLAN AS AN EXISTING CONDITION. IBC ACCESSIBILITY REQUIREMENTS MET ON THE INTERIOR.
08/27/2008 ENGINEERING - FINAL Partial Approval OK FOR TEMPORARY C OF O FOR STOCKING AND FURNISHING ONLY. NOT TO BE OPEN FOR OCCUPANCY FOR PUBLIC ACCESS UNTIL A.D.A. ACCESS AND PARKING IS COMPLETED.
1. PROVIDE MAX. 2% SLOPE IN ALL DIRECTIONS AT HANDICAP PARKING SPACE AND ACCESS AISLE.
2. PROVIDE MAX. 2% CROSS SLOPE AND 5% RUNNING SLOPE ON ACCESS WALKWAY.
3. INSTALL CURBING PER ARCHITECTS DIRECTION.
4. PROVIDE A REVISED AND C.O.T APPROVED SITE PLAN WITH ALL MODIFICATIONS.
5. CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL, DEBRIS, PAINT WASHOUT, GROUT WASHOUT AND ROLL-OFF AT REAR OF BUILDING.

RON 609-7300
08/25/2008 ENGINEERING - FINAL Not ready for Inspection PROVIDE ADA COMPLIANT ACCESS.
PER ADA (28 CFR CH 1 4.3.7) NOWHERE SHALL THE CROSS SLOPE OF AN ACCESSIBLE ROUTE EXCEED 1:50 (2%).
PER ADA (28 CFR CH 1 4.7.6) BUILT UP CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES.

CALL FOR RE-INSPECTION
08/25/2008 ENGINEERING - FINAL Denied CONSTRUCT HANDICAP PARKING AND ACCESS ROUTE TO A.D.A. STANDARDS.