Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2008 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 08/22/2008 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 3/8" I.D X 18" GAS FLEX NOT ADEQUATE FOR 100,000 BTU FURNACE 2. SEAL HOLD IN SIDE OF EXPOSED DUCT ON ROOF 3. SUPPORT ALL ELEC. CONDUIT ON ROOF 4. TIGHTEN LOOSE FITTINGS 5. SEAL FRESH AIR INTAKE CONNECTION TO DUCT ON ROOF 6. FINISH WATER HEATER VENT ON ROOF 7. PROVIDE SHIELDS OVER CANVAS CONNECTORS ON EXISTING AC UNIT 8. SUPPORT DUCT ON ROOF AT FLEX CONNECTOR EXISTING UNIT. 9. LEVEL THE EXISTING AC UNIT 10. TURN THE SLEEPERS ON NEW AC UNITS TO SPAN ROOF JOISTS 11. I.D UNITS ON ROOF 12. PROVIDE AIR BALANCE REPORT 13. PROVIDE AN ELBOW AT CONDENSATE TERMINATION 14. SLOPE CONDENSATE MIN. 1/8" PER FT. |