Permit: T08CM00771

Parcel: 119220510


Addresses:

2721 S CASTLE DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/17/2008 FRAMING Approved IVRS - Inspection :*
09/03/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE 1" CLEARANCE WH B-VENT FROM COMBUSTIBLES
2) MISSING PRESSURE RELIEF LINE TO EXTERIOR
3) BLOCK WH PLENIUM
4) MISSING DRYER VENT TO EXTERIOR
5) HAMMER ARRSTORS MUST BE ACCESSIBLE
08/15/2008 FRAMING Partial Approval 1) NO DWV TEST
2) NEED TO CLARIFY PIPING OF EXISTING GAS LINE TO W/H AND DRYER
3) WILL NEED GAS PRESSURE TEST-NOT ON PERMIT
4) NEED CLARIFICATION ON ELECTRIC W/H CIRCUIT 15 ? ? 14 WIRE
08/08/2008 FRAMING Not ready for Inspection IVRS - Inspection :*