Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/01/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO POST ADDRESS-VISIBLE FROM STREET 2) MISSING POST TENSION TAG AT HOSE BIB 3) EXHAUST FAN AT LAUNDRY ROOM NOT WORKING 4) RECEPTACLE AT KITCHEN BAR NEEDS TO BE BLANKED OFF 5) NEED A SET OF APPROVED PLANS ON SITE |