Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM00712
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/22/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/13/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 ANCHOR BOLTS NEEDED EAST WALL 2) CMSTC 16 STRAPS PER SHEAR AT STAIRWAY WALL 3) H25 BACK GARAGE WALL PER 343 DETAIL 4) CARRY BEARINGS THRU BELLY BAND THRU HOUSE AS CRIPPLE POSTS ON PLANS 5) AIR TEST NEEDED FOR SOLAR |
|
04/28/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) HOLDOWNS AND ANCHOR BOLTS THROUGHOUT 2) FINISH DETAIL OF BLOCKING ABOVE STAIRS |
|
04/25/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SOUTHEAST GARAGE WALL OVER HANGING STEM WALL 2 1/4" 2) CLIP GARAGE KING STUDS, NAIL SHEAR AROUND ELECTRIC PANEL 3) HOLDOWNS AND ANCHOR BOLTS THROUGHOUT 4) LATTERAL BRACE FLOOR TRUSSES 5) 2-2 X 6 HEADER NEEDED IN OPENING BY DOOR ON SOUTH SIDE 6) THA 422'S NEEDED UNDER 2 X BLOCKING BY FRONT DOOR |
|
04/23/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | TOO MANY ITEMS STILL WORKING | |
04/22/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* STILL WORKING |
|
04/21/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) FINISH ROOF SHEATHING 2) ALL HANGERS CLIPS AND H.D.'S DBL STRAPS AT GIRDERS ECT... |