Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM00711
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/27/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/17/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) EXTERIOR CLIP AND NAIL OK 2) INTER HOLDOWNS NEED TO HAVE BIGGER BOLTS AND CHECKED THROUGHOUT |
|
04/16/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COIL STRAPS ON NORTH SIDE INTO STUDS 2) MTTS IN GARAGE NEED 5/8 TITEN OR 3/4" KB11 3) ADD STUDS UNDER BEAMS THROUGHOUT 4) ADD CRIPPLES UNDER LEDGER OF H20 HEATER PLATFORM |