Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM00709
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/14/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) CMSTC 16 STRAPS AT STAIRS TO SHORT 2) RETROS STILL NEEDED SOUTHEAST CORNER 3) ANCHOR SILL PLATE PER SHEAR PLAN BETWEEN HOUSE AND GARAGE 4) ANCHOR BOLT NEEDED SOUTH OF FRONT DOOR 5) 2 X 8 BLOCKING NEEDED ABOVE GARAGE OVERHEAD DOOR PER 340 DETAIL 6) BLOCK BETWEEN JACK RAFTERS PER 307 DETAIL 7) RENAIL FLOOR SHEATHING WHERE SHINERS ARE ABOVE OVERHEAD DOOR 8) BLOCK UPSTAIRS DUCTS MINIMUM 3 SIDES 9) STILL CUTTING PENETRATIONS TO EXTERIOR NORTH WALL 10) SEAL PENETRATIONS IN PAPER UNDER STAIRS 11) STOPPED INSPECTION-NOT READY |
|
04/23/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* RETROS NEEDED SOUTHEAST CORNER |
|
04/17/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) SHEAR PANELS MISSING SOUTH EAST CORNER WITH HOLDOWNS 2) DBL STUD NEEDED UNDER 2 PLY GIRDER IN GREAT ROOM 3) 416 DETAIL MISSED ABOVE FRONT WALL 4) BLOCK SHETHING ABOVE LANDING |