Permit: T08CM00706

Parcel: 141350970

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T08CM00706

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
05/23/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
05/15/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
- VERIFY WEST SETBACK PER PREVIOUS INSPECTION
- ANCHOR BOLT NEEDED UNDER WINDOW IN GREAT ROOM
- ANCHOR BOLTS NEEDED IN FRONT BATHROOM
05/14/2008 EXCAVATION/LAYOUT REBAR & ZON Denied 1) FOUNDATION ANCHORAGE PER SHEAR PLAN ON GARAGE SHEAR WALL (WEST)
2) FOUNDATION ANCHORAGE FOR KITCHEN SHEARWALL
3) SILL PLATE ANCHORAGE FOR SHEARWALL BY FRONT DOOR
4) FILL ALL HOLES IN LTT 20 AT BACK GARAGE SHEARWALL
5) MINIMUM 5 (16D) NAILS IN LEDGER ABOVE FRONT DOOR PER FRAMING PLAN
6) SILL PLATE ANCHORS PER SHEAR PLAN STAIRWAY WALL
7) FIX WEEP SCREED NORTHWEST CORNER OF GARAGE
8) FINISH MESH GARAGE GABLE END
9) SEAL STAPLE PENETRATIONS GARAGE WEST WALL
10) NAIL PROTECT WIRE AT ISLAND
11) OUTSIDE SILL ? LEAKING
12) SUPPORT 3" DRAIN LINE IN GARAGE CEILING
13) NOT READY-STOPPED INSPECTION
03/25/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) COMPLETE 00005 INSPECTION