Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM00705
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/02/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/30/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWNS STILL NOT COMPLETE 2) STUDS WITH HOLDOWNS |
|
05/29/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* - SPECIAL INSPECTION REPORTS FOR ALL HOLD DOWNS AT FRONT GARAGE WALL AND STAIRWAY WALL ON STRAPPED STUDS PER SHEAR |
|
05/28/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWNS AND SPECIAL INSPECTION PER ENGINEERING FIX FOR FRONT STEMWALL IN GARAGE 2) SPECIAL INSPECTION REPORT FOR EPOXY HOLDOWNS FOR STAIRWAY WALL 3) CMSTC16 AT STAIRWAY MUST BE 53" LONG 4) NAIL TOGETHER OVER NOTCHED EXTERIOR 2 X 6 ? KING STUD AND TRIMMER AT STAIRWAY 5) 5-2 X 6 POST UNDER BEAM EAST SIDE FRONT OF HOUSE 6) PATCH HOLE IN PAPER BEHIND STOVE 7) NAIL DOWN SOLE PLATES FOR GYPSUM SHEARWALLS UPSTAIRS PER SHEARPLAN 8) MIN 3/4" FIRESTOP AT TOP OF DUCT CHASE 2ND FLOOR 9) NAIL PROTECT 2" ABS SOLE PLATE MASTER BATH 10) AIR TEST ON SOLAR GLYCOL LINES |
|
04/21/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) HOLDOWNS AND ANCHOR BOLTS AT INTERMEDIATES |
|
04/18/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |