Permit: T08CM00699

Parcel: 120061620


Addresses:

242 E LINCOLN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/11/2008 FRAMING Approved IVRS - Inspection :*
06/09/2008 FRAMING Partial Approval IVRS - Inspection :*
1) PENDING ALL TRADES
05/30/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BEDROOM 2 WINDOWS DO NOT MEET EGRESS 44" MAX 20 X 22 OPENING
2) TERMINATE EXHAUST FANS TO EXTERIOR
3) VENT SHOWER ABS THRU ROOF
4) AIR ADMITTANCE VALVE WILL REQUIRE ACCESS NOT ON PLAN
5) PROVIDE 30" CLEARANCE WATER CLOSET ROOM
6) NAIL PROTECT PLUMBING THROUGHOUT
7) NAIL PROTECT ROMEX BEDROOM 1 WEST WALL
8) PROPERLY BRACE ALL CEILING 2 X 4 ON EDGE TO RAFTERS OR TURN ON EDGE
9) ? AND STRAP LEDGE CONNECTION BEDROOM 1
10) AIR ADMITTANCE VALVES THROUGHOUT NOT ON PLAN VENT THRU ROOF TOP