Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/03/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/19/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RECALL FOR CLOSET FLANGE INSP. WALLS OK |
|
| 08/18/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* COMPLETE LIST FROM 8/15/08 |
|
| 08/15/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV WATER TEST OK SECURE PIPING IN WALLS CORRECT SLOPE AT TRAP ARM KEEP OPEN PIPES CAPPED REMOVE EXCESS FLUX FROM COPPER JOINTS ALL COPPER SHALL BE REAMED COMPLETE PIPE SUPPORTS & SAFETY PLATES LAVITORY ARM CARRIER SPECIFIED |