Permit: T08CM00672

Parcel: 12701004C

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T08CM00672

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
03/27/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/25/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- 135 DEG. CHANGE OF DIRECTION MAX ALLOWED WITHOUT ADDITIONAL CLEANOUT, YOU HAVE 270 DEG.
- USE OF AIR ADMITTANCE VALVE REQUIRES A CITY APPROVED PLAN REVISION
- A LETTER IS NOT ACCEPTABLE TO CHANGE VENTING SYSTEM
- TIE IN POINT OK TO COVER