11/13/2008 | FRAMING | Approved | IVRS - Inspection :* SPECIAL INSPECTION ON LIGHT STEEL WAIVED |
|
10/03/2008 | FRAMING | Partial Approval | IVRS - Inspection :* NEED WELDING SPECIAL INSPECTIONS |
|
08/08/2008 | FRAMING | Partial Approval | IVRS - Inspection :* CANOPY POLES IN PLACE A TO D - OK TO POUR |
|
07/23/2008 | FRAMING | Partial Approval | IVRS - Inspection :* PARKING CANOPIES N.SIDE OF G TO N SIDE OF J 1. NEED #2 BY 14 GA. STRAPS 6" OC DETAIL D 2. PROVIDE WELDING CERTIFICATIONS |