Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T08CM00663
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/30/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
06/24/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. ROUGH SOIL TEST OK 2. CALL BACK FOR PRE-SLAB |
|
06/23/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. 107, 106, 105, 104, 103, ROUGH SOIL TEST OK UNDERGROUND ONLY 2. #102 & #108 REPAIR LEAK AND RETEST ROUGH SOIL |
|
06/20/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. DRAINAGE FITTINGS REQUIRED ON VENTS BELOW FLOOD LEVEL 2. CORRECT SLOPE 3. TEST ALL NEW PIPING 4. FERNCO COUPLINGS NOT ALLOWED 5. VENTING CLOSET STUB IS NOT PERMITTED PER SECTIONS 905.3 AND 706.4 SEE CODE AND ANALYSIS ITEM 6 |
|
06/16/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. INSTALL PRE-APPROVED PLANS AND UPC 2006 2. DID WALK THRU WITH PLUMBER |