Permit: T08CM00656

Parcel: 10511029C


Addresses:

1 W WETMORE RD #101

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/25/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
OK TO COVER UNDERGROUND
03/21/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
CONTRACTOR TO PAY REINSPECTION FEE
03/19/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 712.2 2006 UPC - WATER TEST SHALL BE THRU THE ROOF
2. 706.3 HORIZONTAL x HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP
3. PLUMBING GENERAL NOTE #6 - TO BE TYPE "L" COPPER AFTER INSPECTION WILL NEED TO INSULATE HOT
4. PLAN CALLS FOR HANGERS OR TRAPEEZE - WILL REQUIRE ARCHITECTS APPROVAL OF "ZIP STICKS)
5. ALL PIPING TO BE SUPPORTED PER TABLE 3-2 2006 UPC
6. CONTINUED "NOT READY" WILL RESULT IN A
REINSPECTION FEE

IMPORTANT NOTE: YOU HAVE NOT BEEN GIVEN PERMISSION TO COVER ANYTHING - PLEASE UNCOVER COVERED WORK
03/18/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- TEST TO REVENT HEIGHT ABV CEILING
- CORRECT LEAK ON COPPER JOINT BELOW SLAB
- REDLINE ANY CHANGES
- USE SWEEP AT LAV
03/17/2008 PLUMBING - ROUGH, SOIL Cancelled