Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/25/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* OK TO COVER UNDERGROUND |
|
| 03/21/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR TO PAY REINSPECTION FEE |
|
| 03/19/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 712.2 2006 UPC - WATER TEST SHALL BE THRU THE ROOF 2. 706.3 HORIZONTAL x HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 3. PLUMBING GENERAL NOTE #6 - TO BE TYPE "L" COPPER AFTER INSPECTION WILL NEED TO INSULATE HOT 4. PLAN CALLS FOR HANGERS OR TRAPEEZE - WILL REQUIRE ARCHITECTS APPROVAL OF "ZIP STICKS) 5. ALL PIPING TO BE SUPPORTED PER TABLE 3-2 2006 UPC 6. CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE IMPORTANT NOTE: YOU HAVE NOT BEEN GIVEN PERMISSION TO COVER ANYTHING - PLEASE UNCOVER COVERED WORK |
|
| 03/18/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - TEST TO REVENT HEIGHT ABV CEILING - CORRECT LEAK ON COPPER JOINT BELOW SLAB - REDLINE ANY CHANGES - USE SWEEP AT LAV |
|
| 03/17/2008 | PLUMBING - ROUGH, SOIL | Cancelled |