Permit: T08CM00644

Parcel: 11011369B


Addresses:

4881 E GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08CM00644

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/13/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/11/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. INSTALL VALVE BOX IN WALKWAY
2. RPA DRIPPING
3. EXTEND VENT TERMINATIONS WITHIN 10' OF FORCED AIR INTAKE TO 3' ABOVE INLET
4. CORRECT COUPLING ON CLOSET STUB
5. PROVIDE CORRECT WYE PATTERN FITTINGS REQUIRED FOR HORIZONTAL VENT CONNECTIONS
6. REDLINE ALL PLAN CHANGES I.E. DELETED FIXTURES, AND CHANGES TO SPECS.
7. PROVIDE DOCUMENTATION FOR ALL CHANGES TO PLAN SPECS. I.E. HOSE BIBS, STOPS, SUPPLIES, TRAPS, ETC.
8. SHOWER PAN LINER OK
03/10/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/06/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
03/05/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/04/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/26/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
01/23/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. NEED TO SEE TEST ON SHOWER PAN DRAIN CONNECTION
2. CUT CLOSET BENDS EVEN W/TOP OF RING PRIOR TO SETTING CLOSETS
3. LETTERS RECEIVED FOR DELETION OF LAV CARRIERS AND BRANCH LINE INSULATION
12/16/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ABV. CEILING MAINS INSULATED OK
PROVIDE APPROVAL FOR UNINSULATED BRANCH LINES
1ST LEVEL CLOSET FLANGES OK ALL EXCEPT RM. 105
12/15/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
2ND LEVEL DRAINS OK
12/09/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NOT INSULATED PER PLAN SPECS OR MANUFACTURES INSTALLATION REQUIREMENTS.
2. INSULATE CONTINUOUSLY AND SEAL PROPERLY
3. ALL PIPING, SADDLES AND FIBERGLASS SPECIFIED
4. COMPLETE ALL NOTED CORRECTIONS
11/28/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DWV W/TEST, WATER UNDER LINE PRESSURE.
CORRECT SIZE TO WB.
OK TO INSULATE.
OK TO ONE SIDE WALLS
REDLINE CHANGE
SECURE SINK DRAINS AND SHWR TRAP
SAFETY PLATES MISSING. BACKING.
11/25/2008 PLUMBING - INTERMEDIATE Cancelled CANCELLED PER RON
11/12/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CORRECTION AT 1ST LEVEL TR OK
11/06/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
RM. 105 CORRECT DRAIN INTO VENT
PROVIDE LAV CARRIERS AS SPECIFIED
OK TO COVER WALLS ON 1ST FLOOR AFTER SECURING DRAIN
PIPING, EXCEPT AT CORRECTION. RETEST.
REPAIR BELOW FLOOR OK
11/04/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
REMOVE WALL COVERINGS AND WALL INSULATION WHERE
ABS DWV HAS NOT BEEN TESTED. PROVIDE TEST.
10/31/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
PROVIDE CLEARANCE FOR HW PIPE INSULATION
OK TO INSULATE PIPE IN WALLS ONLY