Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T08CM00638
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/19/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
11/18/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* RESTROOM 173 OK 169 - PROVIDE APPROVED CLOSET FLANGE INSTALLED CORRECTLY |
|
11/12/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. RESTROOM #173 CLOSET FLANGE OK 2. RESTROOM #169 CLOSET FLANGE TO EXTEND 1/4" ABOVE FINISHED FLOOR |
|
10/20/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ADDITION OF FIXTURE FITTING FOR LAVS OK WATER DISTRIBUTION OK WHEN ADDITION OF WATER HAMMER ARRESTOR IS INSTALLED, CAN BE SEEN ON FINAL. |
|
10/09/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) THIS INSPECTION FOR 03005 & 03035 DWV ONLY 2) WATER TEST PER RED LINE ON MENS RESTROOM #173 3) ADDITION OF MOP SINK REQUIRES REVISED CITY APPROVED PLAN 4) PROVIDE DBL FIXTURE FITTING FOR BACK TO BACK LAVS |
|
10/07/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RESTROOM #208 & #165 CLOSET FLANGE OK |
|
09/25/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CAPS FOR SINK AT 219 OK |
|
09/18/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGE OK RESTROOM 145, 139, 126 |
|
08/26/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES IN 146 OK 145 NEEDS SMOOTH INTERIOR WATER WAY & FLANGE TO BE ON TOP OF TILE SURFACE. SHOWER DRAINS DEMO ROOM BACK TO BACK 139 & 126 OK |
|
08/25/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. PROVIDE CAPS ON EXISTING SHOWERS #138 BACK TO BACK 2. RECALL ALL CLOSET FLANGES FOR INSPECTION 3. PROVIDE ACCESS TO EXISTING TRAP PRIMERS AND 3/4" SHUT OFF VALVE IN ROOM 139 NOTE: ALL FIXTURES (KITCHEN) REPLACEMENTS REQUIRE CORRECT DRAINAGE FITTINGS. PUBLIC USE LAVS REQUIRE HOT WATER TO BE 110 DEG. WITH WATER HEATER NOT BEING SOLE CONTROL OF THIS TEMPERATURE |
|
08/19/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SEE NOTE #2 FROM 8/6/08 - CONCRETE POURED W/O INSPECTION 2. INTERMEDIATE NOT READY - NO TEST ON ABS CONTINUED "NOT READY" WILL RESULT IN REINSPECTION FEE |
|
07/09/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR | |
06/18/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER WALLS SUPPORTS ADDED AS REQUIRED 2. NEED TO RECHECK CLOSET FLANGES AFTER FLOOR IS SET |