Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PRE SLAB
Permit Number - T08CM00638
Inspection Description - PLUMBING - PRE SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2008 | PLUMBING - PRE SLAB | Approved | IVRS - Inspection :* | |
08/21/2008 | PLUMBING - PRE SLAB | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
08/06/2008 | PLUMBING - PRE SLAB | Not ready for Inspection | IVRS - Inspection :* 1) OK TO COVER UNDERGROUND AT #126, 139 AB'S WATER TEST OK 2) RECALL 03015 FOR PRE SLAB |
|
08/04/2008 | PLUMBING - PRE SLAB | Not ready for Inspection | 1. AT #145 & #146 - CLOSETS SET BEFORE FLANGE APPROVAL NOTE: REQUIRE 18" CLEAR IN FRONT OF CLEAN OUT 2. AT 126 & 139 - HORIZONTAL VENTING BELOW FLOOD RIM LIMITED TO STRUCTURAL CONDITIONS 3. EXPOSE ALL FITTINGS UNDERGROUND REQUIRE DRAINAGE FITTINGS AT URINAL - COPPER NOT SUPPORTED - NO TEST ON LAVS |
|
06/10/2008 | PLUMBING - PRE SLAB | Partial Approval | IVRS - Inspection :* 1. CORRECTIONS MADE OK OK FOR CONCRETE 2. NOTE: 3" CLEANOUTS REQUIRE 18" OF CLEARANCE IN FRONT 3. THIS INSPECTION FOR ROOMS #145 & #146 |
|
05/28/2008 | PLUMBING - PRE SLAB | Not ready for Inspection | IVRS - Inspection :* PROVIDE LISTING FOR REPAIR COUPLINGS UNDER SLAB NO PIPE WRAPS |
|
05/15/2008 | PLUMBING - PRE SLAB | Not ready for Inspection | IVRS - Inspection :* |