Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM00625

Parcel: 141312660

Inspection Status: Approved

Inspection History: STUCCO MESH

Permit Number - T08CM00625

Inspection Description - STUCCO MESH

Inspection Status - Approved

Date Description Inspector Results Comments
05/01/2008 STUCCO MESH Approved IVRS - Inspection :*
04/28/2008 STUCCO MESH Not ready for Inspection IVRS - Inspection :*
1) STUCCO LATH
2) MISSING LATH REAR WALL
3) MISSING LIGHT BOX EAST GARAGE FRONT (L) A.B.'S AT GARAGE BOTTOM PLATE
4) AT DBL LAV BANG PLATE PEX 1/4" FROM EDGE REQUIRED
5) NO POTABLE H20 PRESSURE, METER NOT CONNECTED
6) REMOVE SHIMS AT NON 3 PT BEARING TRUSSES KIT/LAUNDRY WALL, LEAVE TRUSS DRAWINGS TO VERIFY
6) EXT. CLIP NEVER SIGNED FOR