Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T08CM00612
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2009 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
03/20/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* BALANCE OF FENCE POST HOLES @ N/W SIDE (18) |
|
03/13/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 13 FENCE POST HOLES 18 LEFT AT NW SIDES |
|
03/10/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. REMAINING SKATE AREA FLAT WORK 2. 9 FENCE HOLES SOUTH 1/2 |
|
02/28/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. FENCE POST FOOTINGS SOUTH SIDE AND 36' + OR - ON SE SIDE 2. RFI 2/25/09 ADDED REBAR FOR COMPETITION BOWL OK |
|
02/25/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. COMPETITION BOWL BOTTOM 2. CONFORMATECH SPECIAL INSPECTED 3. WEST SIDE RAMP #3 12" O.C WALLS AND BOTTOM DETAIL BEING SUBMITTED 4. CRUMB OUT |
|
02/11/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* AREAS AROUND COMPETITION BOWL (EAST, NORTH OK TO POUR SLAB; 2 @ CANOPY SOUTH) CAISSONS AS PER DETAIL TYPE #10 PAGE 3000 - OK TO POUR |
|
02/05/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SIDEWALK INFILL ON SOUTH SIDE #3 18" O.C. EACH WAY AND DOWELS TO EXISTING SLAB |
|
01/28/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. SLABS - SOUTH 1/2 OK TO POUR REMAINING 2. HOLES FOR 4 GATE POSTS IN SLAB OK 4' X 12" |
|
01/20/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* WEST SIDE OF KIDNEY BOWL; SURROUNDING SNAKE RIVER |
|
01/13/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 3 - SKATE BENCHES REINFORCEMENT STEEL OK |
|
12/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* KIDNEY BOWL BOTTOM |
|
12/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. FLAT BOTTOM ON SNAKE RUN 2. COMPITATION BOWL WALL AND BOND BEAM EXCEPT W 15' 3. CONFORMA TECH SPECIAL INSPECTED |
|
12/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 4 LIGHT POLE BASES |
|
12/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STEEL REINFORCEMENT @ TOJO SKATE ONLY -- FLAT WORK AT BOTTOM TO BE INSPECTED AND POURED LATER |
|
12/11/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* WORKING ON SNAKE RUN NEED TO CALL BACK BEFORE SHOTCRETE |