Permit: T08CM00576

Parcel: 114475910

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/24/2008 FRAMING Approved IVRS - Inspection :*
03/20/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. BANG PLATE ABS AT TOP PLATES
2. NEED STUD SHOE AT LAV ARM STUD ABS
3. SUPPORT BATH 4 GANG
4. NEED DWV TEST
5. PENINSULA TOP DETERMINING OUTLET