Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T08CM00571
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2008 | FRAMING | Approved | IVRS - Inspection :* | |
04/29/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* - FIX LATERAL BRACE IN FLOOR TRUSS IN GARAGE - NAIL DOWN THROUGH SHEAR PANELS PER 303/508 DETAIL - FHA PLATE DOUBLE TOP PLATES IN GARAGE WHERE OVERNOTCHED FOR AC LINES - SEAL PENETRATIONS IN PAPER UNDER STAIRS - SEAL PAPER AT WATER MAIN IN GARAGE - NAIL DOWN SHEAR PANELS ABOVE KITCHEN PER 508 DETAIL - ANCHOR BOLTS NEEDED THROUGHOUT STOPPED INSP. NOT READY |