Permit: T08CM00568

Parcel: 141351090

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM00568

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/24/2008 FRAMING Approved IVRS - Inspection :*
04/23/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- 2 X 12's PER PLAN AT STAIRWAY LANDING
- FHA PLATES NEEDED KITCHEN WALL WITH OVERKNOTCHED PLATES
- FIRESTOP ABOVE 3" BY FRONT DOOR
04/01/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- STRAP BEAM SOUTH END OF HOUSE
- BELLY BAN TO SHORT SOUTH SIDE, NEED COIL STRAP
- NAIL BOTTOM CHORD GABLE END RAFTER SOUTH SIDE
- ANCHOR BOLT SILL PLATES OF SHEAR PANELS TO PLANS
- NAIL PROTECT PIPES AT SILL PLATES
- (2) 2X SILL PLATES GARAGE WINDOW PER 519.1 DETAIL
- ANCHORS NEEDED AT SILL PLATES WITHIN 12" OF SPLICES
- MAS LEGS ATTACHED TO STUDS ON SHEAR WALL PER HOLD DOWN SCHEDULE

NOT READY INSPECTION STOPPED