Permit: T08CM00567

Parcel: 141351110

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM00567

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/28/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/25/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANCHOR STILL MISSING IN HOLDOWNS AT STAIRWAY
2) ANCHOR NEEDED WITHIN 12" OF SPLICE IN BOTTOM PLATE GARAGE SOUTHWALL 2 PLACES
3) TRIMMERS NEEDED UNDER BACK SIDE OF H20 HEATER PLATFORM
4) H2.5 OR A35 NEEDED AT STIAR STRINGERS PER 347 DETAIL
5) BLOCK NEEDED AT SEAM OF SHEAR PANEL MAIN FLOOR BATH
04/24/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- HOLD DOWNS IN GARAGE NOT NAILED
- NEED SPECIAL INSPECTION REPORT ON CHEMICAL ANCHORS
04/08/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) 2 RETRO NORTH WEST GARAGE WALL AND 1 RETRO KIT WINDOW
04/07/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RSP4 GABLE ENDS
2) FINISH SHEAR AT FRONT DOOR
3) FINISH NAILING BELLY BAND
4) NAIL PROTECT PIPES BOTTOM PLATES
5) HOLDOWNS AND ANCHORS THRU-OUT
04/04/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RETRO NEEDED FOR STHD 14 BY KITCHEN WINDOW
2) RETROS NEEDED FRONT OF GARAGE
3) STRAPS MISSING THRU-OUT
4) FINISH NAILING BELLY BAND THRU-OUT
5) FINISH NAILING SHEAR PANELS PER DETAILS
6) STOPPED INSPECTION
04/03/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER MIKE