Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM00561

Parcel: 141351010

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM00561

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/06/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/14/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) BOLTS NEEDED IN HOLDOWNS
04/11/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) 602 DETAIL FOR BEAM IN GARAGE CALL FOR STRAP OVER TOP OF BEAM
2) NAIL PROTECT PIPES AT SILL EXTERIOR
3) HOLDOWNS STILL NOT DONE
4) STUDS STILL NOT VERT. NAILED FROM PREVIOUS INSPECTION
04/09/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval 1) ADD WIND BRACE SOUTH SIDE
2) MISSED TWO P.A.'S REAR WALL (MARKED)
3) VERT NAIL ALL STUDS CONNECTED TO H.D.