Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/14/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) BOLTS NEEDED IN HOLDOWNS 2) RETRO NEEDED TO BE COMPLETED (3 OF THEM) |
|
| 04/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COIL STRPS MISSING PER 522 DETAIL INSIDE GARAGE WALL 2) BOLT NEEDED IN RETRO HOLDOWN SOUTH WALL 3) BLOCKING NEEED IN FLOOR TRUSS OF LIVING ROOM PER PALN 4) NAIL TRIMMER TO KING STUD PER GENERAL NOTES (3" ON CENTER PER CARLOS) 5) DBL 2 X 6 POST UNDER GIRDER RAFTER MAIN FLOOR WEST SIDE 6) RETRO NEEDED FOR HOLDOWN UNDER KITCHEN WINDOW WEST OF WINDOW 7) NAIL PROTECT PLUMBING AT SILL PLATES 8) 2-CS16 NEEDED NORTH WALL 9) BOLT NEEDED IN RETRO NORTH WALL |
|
| 04/10/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED TO MANY ITEMS 2) RAFTER FIX FOR F1 RAFTER ABOVE MASTER BATH AND CLOSET |