Permit: T08CM00457

Parcel: 110055340

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T08CM00457

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
03/26/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/25/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
3" CO REQUIRED ON 3" SINK DRAIN
CLOSET BEND IS TOO HIGH TO ALLOW FLANGE INSTALLATION
INSTALL FOAM WRAPS FOR PRE-SLAB
03/24/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- 1/4" PER FOOT SLOPE REQUIRED
SEE UPC SEC 208
- VERTICAL TO HORIZONTAL CHANGES OF DIRECTION SHALL BE MADE WITH WYE PATTERN FITTINGS (SWEEP) 706.4 AND 706.1
- CONTRACTOR SHALL PAY A REINSPECTION FEE FOR FAILURE TO COMPLY W/PREVIOUS CORRECTIONS