Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T08CM00457
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 03/25/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 3" CO REQUIRED ON 3" SINK DRAIN CLOSET BEND IS TOO HIGH TO ALLOW FLANGE INSTALLATION INSTALL FOAM WRAPS FOR PRE-SLAB |
|
| 03/24/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - 1/4" PER FOOT SLOPE REQUIRED SEE UPC SEC 208 - VERTICAL TO HORIZONTAL CHANGES OF DIRECTION SHALL BE MADE WITH WYE PATTERN FITTINGS (SWEEP) 706.4 AND 706.1 - CONTRACTOR SHALL PAY A REINSPECTION FEE FOR FAILURE TO COMPLY W/PREVIOUS CORRECTIONS |