Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE LEFT GAS CARD |
|
| 05/07/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* PROVIDE A PRESSURE RELIEF VALVE RATED FOR THE BTU DEMAND AT POOL HEATER RESCHEDULE PLUMBING FINAL |
|
| 02/08/2008 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled | |
| 02/07/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE MINIMUM 10 PSI TEST ON ENTIRE GAS SYSTEM AND INTO HEARTH OF FIREPLACE WITH TEST GAUGE IN 1/10 POUND INCREMENTS AT TIME OF REINSPECTION. POOL HEATER REQUIRES 90 DEG. TURN DOWN ON PRESSURE RELIEF. PROVIDE PROOF OF NEW MECHANICAL UNIT INSPECTION OR PROVIDE PERMIT WITH INSPECTION APPROVAL. |