Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/04/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWNS IN GARAGE/HOUSE WALL REQUIRE 7" MIN EMEDMENT 2) NAIL HTT 16'S BATHROOM WALL 3) FINISH NAILING FHA PLATE 4) NAIL PROTECT SOLAR LINES 2ND FLOOR |
|
| 04/03/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RETRO NEEDED SOUTH EAST CORNER DBL STUD 2) ANCHORS STILL NEEDED IN HOLDOWNS CENTER WALL 3) ANCHOR BOLTS NEEDED THRU OUT 4) BLOCKS NEEDED FOR TOPS OF GYPSUM SHEARWALLS 5) HANGERS NEEDED PER 334 DETAIL IN GARAGE 6) BLOCK NEEDED AT CEILING IN BATH UNDER STAIRS EXTERIOR WALL 7) FINISH NAILING OF FHA PLATES UPSTAIRS MASTER CLOSET 8) NAIL PROTECT SOLAR LINES |
|
| 03/14/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) HOLDOWN AND ANCHORS NEEDED THRU-OUT 2) RETRO NEEDED FOR FRONT SHEAR PANEL BY DOOR |