Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T08CM00390
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/09/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
08/05/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NEED TO SEE FLANGES FASTENED TO FINISHED FLOOR |
|
08/04/2008 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - RI canceled | |
07/14/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE A WATER TEST ON DWV 2. INSTALL SWEEP ON DF TRAP ARM 3. PLAN SPECIFIES LAV CARRIERS 4. SUPPORT HORIZONTAL ABS ABV CEILING AT EACH END AND NOT TO EXCEED 4', IN WALL TO AVOID CONTACT W/SHARP METAL 5. WOMENS CLOSET STUB NOT 18" FROM SIDE WALL |
|
06/26/2008 | PLUMBING - INTERMEDIATE | Partial Approval | OK FOR CONCRETE | |
06/12/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ROUGH SOIL ONLY OK TO COVER HARD CAP TEST TEE INSTALL FOAM PIPE WRAPS PRIOR TO CONCRETE ALSO, INSTALL FCO's IF SHOWN ON SHELL PLAN ON FUTURE PROJECTS; INSTALL ABOVE SLAB TEST FITTINGS ON ROUGH, SO THAT EACH JOINT GETS A WATER TEST. THANKS. |