Permit: T08CM00385

Parcel: 10511061R

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM00385

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/31/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
1. CORRECTIONS MADE OK
2. PLUMBING FINAL OK
03/28/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
- I DON'T SEE WHERE THESE TUBS ARE CONNECTED
PER THE PLAN
- WHERE IS THE P-TRAP, VENT, ETC?
- HOW IS THE CONNECTION BETWEEN PVC AND N/H MADE?
- WHERE IS THE WATER HEATER PAN DRAIN?
- HAMMER ARRESTORS REQUIRED AT WASHER BOX
03/27/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
03/26/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CONNECT ALL OF THE FOOT SPAS
REC'D CLEAN BACTERIA REPORT ON SITE
03/25/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
03/17/2008 PLUMBING - FINAL Cancelled IVRS - RI canceled