Permit: T08CM00384

Parcel: 136190560


Addresses:

3318 S MEAD AV


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T08CM00384

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/10/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
02/29/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE A SECONDARY DRAIN OVERFLOW SENSOR
- PROVIDE A HOSE CLAMP ON PUMP & AT TRANSITION TO COPPER
- REMOVE ALL TAPE FROM VENT CONNECTOR & PROVIDE
MIN. 3 SCREWS IN EACH JOINT
- DO NOT CUT THE PLUG OFF OF THE CONDENSATE PUMP
- FUSE STAT NOT REQUIRED
- PROVIDE A ROMEX CONNECTOR ON FURNACE CORD
- 3/8" X 48" GAS FLEX NOT ADEQUATE FOR 75,000 BTU & CANNOT EXCEED 3' IN LENGTH
- EXTEND FURNACE VENT MIN. 2' ABOVE COMBUSTION AIR INTAKE