Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM00362
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/12/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/28/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER DON |
|
04/24/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED ENGINEERING FOR STRAPS REAR PA HD |
|
04/17/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) MSTR STRAP REVISION NEEDED 2) ROOF PERIMETER NOT NAILED 3) REAR P.A. H.D. REVISION |
|
04/14/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MSTC40 STRAPS REQUIRED ON WEST SIDE OF GARAGE OPENING 2) UNABLE TO GET 2? NAILS BEYOND CLEAR SPAN ON MST40 STRAP WITHOUT NAILING TO ROUGH SAWN GARAGE BEAM (HEADER) 3) GARAGE FRONT PLATE H.D.'S GAP BETWEEN HARDWARE AND STUD, NAIL STUDS TO OSB, NAILED TO PHD VERTICALLY 4) CHECK MIN, DRILLING DISTANCE LPI, TJI 3" HOLE FROM BEARING 3 1/2" 5) REAR WALL P.A.'S 1ST & 2ND FLOOR STRAPS NOT WORKING, MISSING REQUIRED NAILS, LAYOUT FOR P.A.'S SW4 BLOCKED DRYWALL AT CLEAR STORY DBL BLOCKS ? 6) FRONT PORCH POST 7) 2ND FLOOR SHEAR TRANSFER 6/6.2 8) MISSING NAILS ON ROOF 3" ON CENTER STAPLES AT PERIMETERS, OSB TURNED OPPOSITE T.J.I. BLOCK BELOW |