Permit: T08CM00305

Parcel: 113076160


Addresses:

1745 E GLENN ST 10


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM00305

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/27/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
1. PLEASE LEAVE A NAME AND CONTACT NUMBER WHEN SCHEDULING THIS INSPECTION
2. SALES OFFICE LOCKED

REINSPECTED:
PLAN CORRECTION SHOWS WATER CLOSET VENT SEPARATE FROM WASHER & KS
OK TO COVER
02/06/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. NOT INSTALLED PER PLAN
2. WET VENTED SECTION FROM KS TO WC TO BE 3"
3. TRAP FOR WASHER TO BE ROUGHED IN A MINIMUM OF SIX INCHES ABOVE FINISHED FLOOR MAXIMUM OF 18" ABOVE FINISHED FLOOR. STAND PIPE TO BE 18"-30" IN LENGTH
4. NOTE: HAMMER ARRESTORS REQUIRED AT WASHER BOX