Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2008 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 02/26/2008 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* STILL NEED TO FINISH PLUMBING NOTES FROM PREVIOUS INSPECTION. PROVIDE THE DEVICE TO LEAVE FIREPLACE DAMPER OPEN MIN. 1" LEFT GAS CARD |
|
| 02/20/2008 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* PRESSURE TEST OK INSTALL A LOG LIGHTER VALVE OUTSIDE OF FIREPLACE NOT A QUARTER TURN GAS LOCK. FIREPLACE IS DESIGNED FOR WOOD. LOG LIGHTER VALVE MAY BE USED WITH A DECORATIVE APPLIANCE SECURE STRUT TO WALL. WILL NEED TO SECURE PIPING AT VALVE TO NEW FURNACE AT TIME OF INSTALLATION RECALL FOR INSPECTION TO OBTAIN GAS CLEARANCE AFTER INSTALLING APPLIANCE |
|
| 02/11/2008 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - REMOVE TEE FOR BARBEQUE LOCATED BELOW WOOD OVER HANG. - RETEST - REMOVE SHARP EDGES FROM STRUT ON ROOF. 1 1/2" MIN. CLEARANCE ABV ROOF REQUIRED. - PLAN REQUIRED FOR NEW INSTALLATION OF GAS SYSTEM - HAVE APPROVED VALVES ON SITE |
|
| 02/01/2008 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE A CITY APPROVED PLAN SHOWING NEW GAS SYSTEM. - INCLUDE LOCATION OF BARBEQUE AND OVERHEAD PORCH AS WELL AS BTU DEMANDS AND DISTANCE - PROVIDE PIPE CLAMPS ON PIPING. - DO NOT USE CONDUIT CLAMPS - PIPING MAY NOT TOUCH ROOF - PROVIDE SUPPORTS IN ALL AREAS - PROVIDE AGA VALVES - INSTALL FURNACE AND HAVE IT INSPECTED |